Chapter 9 Conveying
Dilute phase pneumatic conveying design - spreadsheet.
Links - links


Answers to problems:
See the above spreadsheet for these.
Change only the cells with the yellow shading.

The largest pipe diameter provides the lowest pressure drop, but a larger volume of gas must be blown down it for the same velocity compared to a narrower diameter pipe. For a full analysis, you should consider both pressure and gas volume flow and provide an economic analysis including capital cost of the blower. At least this simple modelling approach helps to provide a format for such a design. However, it is only valid for dilute phase pneumatic conveying.